This pump is designed for dirty water applications and for
continuous use.
The pump can be operated in either a vertical or horizontal position.
The pump can only be operated with water inside and should never
be run dry.
Model 2780 features
water detection technology
.
After 15
seconds, Model 2780 will attempt to turn itself on automatically (if
water is present) and will try again every 10 minutes. This will occur
a total of 5 times. It will then try to start once every 24 hours for 30
days. After this it will stop and you will need to disconnect and plug
the pump back into an electrical power source to reset itself.
Attention
Make sure the outlet (discharge) pipe is empty of water when starting
the pump. Air pockets inside the outlet line can have a negative effect
on the pump performance. If air pockets exist, turn the pump off and
wait a few seconds before turning back on. This should correct the
problem.
Noise generated in Models 1430 and 2100 for short periods
(usually at start up) is caused by the pumps ability to clean itself by
turning repeatedly back and forth (clockwise and counter clockwise),
removing any debris that can block the pre-chamber. This self-clean
ing function reduces the time necessary for maintenance.
Warranty
Lifegard Aquatics warrants to the original purchaser, this product to be
free from defects in material or workmanship for a period of one year
from the date of purchase, provided it is operated in accordance with
factory instructions and operated within the environment and limitations
for which it is designed. Lifegard will not be liable for any labor cost of
removing or replacing component parts. This shall be the responsibility
of the original purchaser as will be shipping charges to and from the
Lifegard facility. Damage incurred by improper repackaging or in shipping
is not covered by this warranty. Lifegard will only be responsible for
repair or replacement of any of its products or parts that are found to
be defective and will not bear cost of any incidental or consequential
damages arising out of the occurrence of such defect. This warranty gives
you specific legal rights that vary from state to state.
Safety Standards
WARNING – To reduce the risk of electric shock, use only on portable
self-contained fountains no larger than 5 feet in any dimension.
WARNING – To reduce risk of electric shock, connect only to a
properly grounded, grounding type receptacle.
CAUTION – This pump has been designed for use with water only.
WARNING – Risk of electric shock – this pump has not been
investigated for use in swimming pool or marine areas.
WARNING – To reduce the risk of electric shock, install only on a
circuit protected by a ground-fault circuit Interrupter (GFCI).
Acceptable for indoor and outdoor use.
Submersible Pump.
Make sure the power cable is fully intact
before connecting the pump to main power
supply.
Never replace or repair the power cable.
Replace entire pump if damaged.
WARNING – Make sure the pump is
disconnected before performing any
maintenance. If plug or main electrical
socket is wet, disconnect the master
switch before removing power cable.
Ideally, extension cords should not be
used. If necessary, make sure connection is
completely sealed and that cable is suitable
for external use and identical to that of the
pump cable (in terms of insulation and
section).
Avoid lifting the pump by means of the
power cable during installation and
maintenance operations.
The pump can be used in liquids with
temperatures no greater
than 95 degrees F.
Keep these instructions
in a safeplace for future
reference.
Keep out of reach of
children.
Cleaning
Easy simple cleaning is required for the pump to operate correctly.
Disconnect the power cord form electrical supply before performing
any maintenance.
Remove the bottom grill (A) by pushing release tabs (Y).
Rinse all parts in running water using a small brush to remove
any debris.
Make sure pre-chamber (C) is clean of any debris.
Maintenance
Remove the bottom grill (A) by pushing the release tabs (Y).
Loosen screw (I) and gently remove the pre-chamber (C) and rotor
assembly composed of the shaft (EFH) and the rotor (G). Remove the
rotor (G) being careful not to lose the rear rubber cap (H). Rinse all
parts in running water using a small brush to remove any scale.
Clean the o-ring (D) fitted on the pre-chamber (C) and make sure it is
clean and in good condition. Replace if it is damaged.
Reassemble the pump.
Dirty Water Pump Series
INSTRUCTIONS
Y Y
A
B
D
EFH
I
C
G
Replacement Parts
R440475 Shaft Assembly-includes bushings (978)
R440476 Impeller (978)
R440477 "O" Ring (978)
R440478 Grid (978)
R440479 Shaft Assembly-includes bushings (1430, 2100)
R440481 "O" Ring (1430, 2100, 2780)
R440482 Grid (1430, 2100, 2780)
R440483 Impeller (1430)
R440484 Impeller (2100)
R440486 Shaft Assembly-includes bushings (2780)
R440487 Impeller (2780)
Phone: 800-628-8771
Fax: 800-424-1445
Web Site: www.lifegardaquatics.com
Page view 0
1

Summary of Contents

Page 1 - Dirty Water Pump Series

UseThis pump is designed for dirty water applications and for continuous use.The pump can be operated in either a vertical or horizontal position.T

Comments to this Manuals

No comments